86 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 ? 805-486-4565 fax 805-487-8911 www.condorpower.com specifications: input ac input: 90-264 vac continuous range, 47 to 63 hz. 750 w units fused for 15 a. 1000 w units fused for 20 a. power factor: 0.99 typical at full load. meets en61000-3-2 class a. inrush: cold start ac current is less than 50 a at 115 vac and 100 a at 230 vac for 500 w and 750 w models; 90 a at 115 vac and 180 a at 230 vac for 1000 w models. limited by thermistor. brownout protection: continuous range units hold regulation to 85 vac. holdup time: 20 ms minimum after removal of power at full load. efficiency: 75% typical. ac power fail: provides ttl ?0? 5 ms before output voltage goes out of regulation band upon loss of power. output adjustability: user adjustable 5% minimum. line & load reg: 1% over ac input range and 0 to 100% load change. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense: compensates for 250 mv total line drop. open sense lead protection. (see redundancy, below.) temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response: output voltage returns to within 1% in less than 500 s for a 50% load change. peak transient does not exceed 5%. overload protection: all outputs are protected against overload and short circuit. automatic recovery upon removal of fault. overvoltage protection: protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. remote inhibit: contact closure to the negative sense line or a ttl level ?0? turns off dc output. dc power good (5 v outputs): provides a ttl ?1? open collector when output is above 4.6 v nominal. redundancy: external or-ing diodes and forced current sharing provide ?n+1? capability. remote sense (+s) compen- sates for additional 0.6 v diode voltage drop. when the current sharing terminal is connected between units, current sharing remains within 10% of the unit?s full output current rating. reverse voltage: protected against reverse voltage up to supply current rating. environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50c at full ratings. safety agencies: most models are approved to ul1950; csa 22.2 #234; iec 950 and tv en60950, class 1 selv., ce 72/23/ eec/93/68eec (low voltage directive). conducted rfi: meets fcc part 15, class a; en55022 class b. output isolation: isolated from ground 50 vdc. cooling: self cooled by internal ball-bearing fans. options: consult factory for available options. features: forced current sharing for n +1 redundancy universal ac input 0.99 typical power factor low ripple and noise dc power good and ac power fail signals true remote inhibit monotonic turn-on and turn-off SPF-500, spf-750, spf-1000 commercial series 500-1000 watts single output, forced current sharing n o i t c n u f * c a v 5 1 1 c a v 0 3 2 r o t c e n n o c ) l ( - 1 b te n i l1 e n i lp i r t s r e i r r a b ) n ( - 1 b tl a r t u e n2 e n i ls r e t n e c 8 / 3 s w e r c s 2 3 - 6 # ) d n g ( - 1 b td n u o r g y t e f a sd n u o r g y t e f a s n o i t c n u f l e d o m n o i t a c o l r o t c e n n o c t u p t u os l e d o m 0 0 5 - f p s l l av + l a n i m r e tl p 2 s w e r c s 2 3 - 8 # s r a b s u b v - l a n i m r e t e g a t l o vs l e d o m 0 5 7 - f p s l l av + l a n i m r e tl p 2 s w e r c s 0 2 - 4 / 1 # s r a b s u b v - l a n i m r e t 8 4 , 6 3 , 8 2 , 4 2 - 0 0 0 1 - f p sv + l a n i m r e tl p 2 s w e r c s 2 3 - 0 1 # s r a b s u b v - l a n i m r e t n o i t c n u f 0 0 5 - f p s 0 5 7 - f p s 0 0 0 1 - f p s r o t c e n n o c e s n e s e t o m e r) + s ( 2 - 1 j) + s ( 5 - 1 j) + s ( 7 - 3 je p y t a t m p m a ) - s ( 1 - 1 j) - s ( 4 - 1 j) - s ( 8 - 3 j) w 0 0 5 - 1 j ( 6 - 6 5 4 0 4 6 # d o o g r e w o p7 - 1 j3 - 1 j5 - 3 j) w 0 0 5 - 2 j ( 3 - 6 5 6 0 4 6 # r o t i b i h n i5 - 1 j2 - 1 j4 - 3 j) w 0 5 7 - 1 j ( 6 - 6 5 6 0 4 6 # r o e r a h s t n e r r u c6 - 1 j6 - 1 j6 - 3 j - 3 j ( 8 - 6 5 4 0 4 6 # r o ) w 0 0 0 1 l i a f r e w o p c a8 - 1 j1 - 1 j3 - 3 j) g n i k c o l ( s r e d a e h n i p e g a t l o v n a f . x u a) v 2 1 + ( 1 - 2 ja / n) v 2 1 + ( 1 - 3 j ) n t r ( 2 - 2 ja / n) n t r ( 2 - 3 j d n u o r g l a n g i s0 1 - 1 ja / na / n ac input (90-264 vac continuous range) dc output status and control
87 condor d.c. power supplies, inc., 2311 statham parkway, oxnard, ca 93033 800-235-5929 805-486-4565 fax 805-487-8911 www.condorpower.com SPF-500, spf-750, spf-1000 single output SPF-500, spf-750, spf-1000 mechanical specifications SPF-500 3.8 lb - 1.7 kg spf-750 4.7 lb - 2.1 kg dimensions: inches millimeters spf-1000 10.4 lb -4.7 kg commercial model power out output no. output output minimum output to t a l maximum regulation SPF-500-12 500 1 +12 v 0 a 42 a 1% SPF-500-15 500 1 +15 v 0 a 34 a 1% SPF-500-24 500 1 +24 v 0 a 21 a 1% SPF-500-28 500 1 +28 v 0 a 18 a 1% SPF-500-48 500 1 +48 v 0 a 10.4 a 1% spf-750-12 750 1 +12 v 0 a 62 a 1% spf-750-15 750 1 +15 v 0 a 50 a 1% spf-750-24 750 1 +24 v 0 a 31 a 1% spf-750-28 750 1 +28 v 0 a 27 a 1% spf-750-48 750 1 +48 v 0 a 16 a 1% spf-1000-24 1000 1 +24 v 0 a 42 a 1% spf-1000-28 1000 1 +28 v 0 a 36 a 1% spf-1000-36 1000 1 +36v 0 a 28 a 1% spf-1000-48 1000 1 +48 v 0 a 21 a 1%
|